ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P24C6-92 PM Sensor Temperature Circuit Range/Performance
DTC Description: P24C6-92
N502633150000100ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P24C6-92
PM Sensor Temperature Circuit Range/Performance
[PM sensor temperature circuit range/performance]
A
Diagnosis condition
  • Ignition switch is "ON" position.
  • 6 hours or more have passed since the last time the ignition switch was turned "LOCK" (OFF) position.
  • Exhaust gas temperature sensor No. 3 (Downstream SCR-DPF temperature) is more than –30°C and is less than 80°C.
  • Exhaust gas temperature sensor No. 2 (Downstream DOC temperature) is more than –30°C and is less than 80°C.
Signal (terminal)
PM sensor.
Threshold
The value of A below is 45.5°C or more.
  • A: B – average value of C and D.
  • B: PM sensor temperature.
  • C: Exhaust gas temperature sensor N0. 3 temperature (Downstream SCR-DPF temperature).
  • D: Exhaust gas temperature sensor No. 2 temperature (Downstream DOC temperature).
Diagnosis delay time
None.
B
Diagnosis condition
  • Ignition switch is "ON" position.
  • 6 hours or more have passed since the last time the ignition switch was turned "LOCK" (OFF) position.
  • Intake air temperature is more than –6.64°C.
Signal (terminal)
PM sensor.
Threshold
PM sensor temperature is less than –39°C.
Diagnosis delay time
None.
POSSIBLE CAUSE
  • Failed diesel fuel system
  • Failed PM sensor.
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position.
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P24C6-92 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.