ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P33FE-1E Backflow pump
Diagnosis Procedure: P33FE-1E
N502633370000800ENG
1.Check other diagnosis code
Check whether the following diagnosis codes are set (Refer to METHOD OF READING AND ERASING DIAGNOSIS CODES).
  • P203A-01: Reductant level sensor A
  • P205A-11: Reductant tank temperature sensor
  • P205A-12: Reductant tank temperature sensor
  • P205A-1C: Urea Tank Temperature Sensor Circuit Range/Performance
  • P20FA-11: Reductant pump B
  • P20FA-12: Reductant pump B
  • P20FA-13: Reductant pump B
  • P20FA-92: Reductant pump B
  • P33FF-1C: Power supply error(urea tank temperature sensor)
  • U0619-00: Lost communication(reductant level sensor A)
  • U1353-81: SENT communication error(urea tank temperature sensor)
Is any diagnosis code set?
YES
Perform the troubleshooting of the diagnosis code (Refer to DIAGNOSIS CODE CHART).
NO
2.Measurement of urea back flow pump resistance
Measurement of urea back flow pump resistance (Refer to UREA PUMP CHECK).
Is the check result normal?
YES
NO
Replace the urea pump (integrated with urea back flow pump) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
3.Check short circuit to earth between DCU and urea pump (urea back flow pump) circuit
  1. Disconnect DCU connector and urea pump connector.
  2. Check the harness side.
  3. Check continuity between DCU connector and urea pump connector.
    DCU
    Urea pump
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-129
    10
    G-54
    6
    Continuity exists (2 Ω or less)
    32
    7
  4. Check continuity between DCU connector and body earth.
    (+)
    (–)
    Continuity
    DCU
    Connector
    Terminal
    A-129
    10
    Body earth
    No continuity
    32
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Check short circuit between DCU and urea pump (urea back flow pump)
  1. Disconnect DCU connector and urea pump connector.
  2. Check the harness side.
  3. Check continuity between DCU connector and body earth.
    DCU
    DCU
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-129
    10
    A-129
    32
    No continuity
  4. Check harness wire and connector damage between DCU connector and urea pump connector.
    DCU
    Urea pump
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-129
    10
    G-54
    6
    Good condition
    32
    7
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
5.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P33FE-1E).
Is diagnosis code No. P33FE-1E set?
YES
Replace the urea pump (integrated with urea back flow pump) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY). Then GO TO 6.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
6.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P33FE-1E).
Is diagnosis code No. P33FE-1E set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
The check is end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.