ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P33FF-1C Power supply error(urea tank temperature sensor)
Diagnosis Procedure: P33FF-1C
N502633400000800ENG
1.Check battery
Check battery (Refer to Electrical & Power Control – Chassis Electrical – Battery – On-Vehicle Service – BATTERY TEST).
Is the check result normal?
YES
NO
Charge the battery, replace the battery, or repair the terminal part (Refer to Electrical & Power Control – Chassis Electrical – Battery – Battery – BATTERY REMOVAL AND INSTALLATION).
2.Check TLC sensor power supply circuit
  1. Disconnect urea pump module connector.
  2. Check the harness connector side.
  3. Turn the ignition switch to the "ON" position.
  4. Check voltage between urea pump module connector and body earth.
    (+)
    (–)
    Voltage
    Urea pump module
    Connector
    Terminal
    G-53
    11
    Body earth
    Battery voltage
  5. Disconnect DCU connector and urea pump module connector.
  6. Check harness wire and connector damage between DCU connector and urea pump module connector.
    DCU
    Urea pump module
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-129
    89
    G-53
    11
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Check TLC sensor earth circuit
  1. Disconnect DCU connector and urea pump module connector.
  2. Check the harness connector side.
  3. Check continuity between DCU connector and urea pump module connector.
    DCU
    Urea pump module
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-129
    41
    G-53
    13
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between DCU connector and urea pump module connector.
    DCU
    Urea pump module
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-129
    41
    G-53
    13
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P33FF-1C).
Is diagnosis code No. P33FF-1C set?
YES
Replace the urea tank assembly [integrated with urea pump module (TCL sensor)] (Refer to UREA TANK REMOVAL AND INSTALLATION). Then GO TO 5.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
5.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P33FF-1C).
Is diagnosis code No. P33FF-1C set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
The check is end.
BookmarkedToo many bookmarks.