ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - U029D-00 Lost communication(NOx sensor A)
Diagnosis Procedure: U029D-00
N502633460000A00ENG
1.Check fuse
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Check the following fuse in the fusible link, fuse holder 2.
    Location
    Signal name
    Fuse No.
    Capacity
    Fusible link, fuse holder 2
    NOx sensor No. 1
    F30
    15 A
Is the check result normal?
YES
NO
Perform the procedures for a blown fuse (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – INSPECTION SERVICE POINTS FOR A BLOWN FUSE).
2.Check continuity of NOx sensor No. 1 power supply line
  1. Disconnect the urea SCR relay connector and NOx sensor No. 1 connector.
  2. Check the harness connector side.
  3. Check continuity between urea SCR relay connector and NOx sensor No. 1 connector.
    Urea SCR relay
    NOx sensor No. 1
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-61
    4
    A-128
    1
    Continuity exists (2 Ω or less)
  4. Check continuity between NOx sensor No. 1 connector and body earth.
    (+)
    (–)
    Continuity
    NOx sensor No. 1
    Connector
    Terminal
    A-128
    1
    Body earth
    No continuity
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Check NOx sensor No. 1 earth line
  1. Disconnect NOx sensor No. 1 connector.
  2. Check the harness connector side.
  3. Check continuity between NOx sensor No. 1 connector and body earth.
    (+)
    (–)
    Continuity
    NOx sensor No. 1
    Connector
    Terminal
    A-128
    2
    Body earth
    Continuity exists (2 Ω or less)
    5
  4. Check harness wire and connector damage between NOx sensor No. 1 connector and body earth.
    NOx sensor No. 1
    Body earth point
    Damage check
    Connector
    Terminal
    No.
    A-128
    2
    2
    Good condition
    5
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Check continuity of NOx sensor No. 1 CAN bus line
  1. Disconnect the DCU connector and NOx sensor No. 1 connector.
  2. Check the harness connector side.
  3. Check continuity between DCU connector and NOx sensor No. 1 connector.
    DCU
    NOx sensor No. 1
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-129
    87
    A-128
    4
    Continuity exists (2 Ω or less)
    65
    3
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
5.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: U029D-00).
Is diagnosis code No. U029D-00 set?
YES
Replace the NOx sensor No. 1 (Refer to UREA SCR SYSTEM SENSORS REMOVAL AND INSTALLATION).
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).