Diagnosis Code No. | M.U.T.-III SE Screen Item [Diagnosis item] | Diagnosis Code Detection Condition | |
U04A4-00 | Invalid Data Received from PM Sensor [Invalid data received from PM sensor] | Diagnosis condition | Ignition switch is "ON" position. |
Signal (terminal) | PM sensor | ||
Threshold | When the communication data length error is judged between the DCU and the PM sensor. | ||
Diagnosis delay time | None. | ||