ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - U059E-00 Invalid data(NOx sensor A)
DTC Description: U059E-00
N502633600000800ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
U059E-00
Invalid data(NOx sensor A)
[Invalid data received from NOx sensor No. 1]
Diagnosis condition
Ignition switch is "ON" position.
Signal (terminal)
NOx sensor No. 1
Threshold
When the communication error is judged between the DCU and the NOx sensor No. 1.
Diagnosis delay time
None.
POSSIBLE CAUSE
  • Failed harness and connector in CAN bus line.
  • Failed NOx sensor No. 1.
  • External noise input.
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position.
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. U059E-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.