1.Connector check: joint connector (CAN2)
CAUTION:
The strand end of the twist wire should be within 10 cm from the connector (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When checking the joint connector (CAN2), ensure that its wiring harness side and its short pins are not damaged.
Is the check result normal?
YES
NO
Repair a defective connector or replace the joint connector (CAN2).
2.Resistance measurement at joint connector (CAN2)
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect joint connector (CAN2) connector.
Check the harness connector side.
Check resistance between joint connector (CAN2) connector terminals.
Joint connector (CAN2) | Joint connector (CAN2) | Resistance |
Connector | Terminal | Connector | Terminal |
A-105 | 13 | A-105 | 14 | 120 ± 20 Ω |
Is the check result normal?
YES <Within 120 ± 20 Ω>
NO <Not within 120 ± 20 Ω>
3.Resistance measurement at engine-ECU connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Check the equipment side.
Check resistance between engine-ECU connector terminals.
Engine-ECU | Engine-ECU | Resistance |
Connector | Terminal | Connector | Terminal |
A-10 | 221 | A-10 | 222 | 120 ± 20 Ω |
Is the check result normal?
YES <Within 120 ± 20 Ω>
Repair the wiring harness between joint connector (CAN2) and engine-ECU connector.
NO <Not within 120 ± 20 Ω>
Check the engine-ECU connector, and repair if necessary. If the engine-ECU connector is in good condition, replace the engine-ECU (Refer to Engine – Diesel Fuel <4N1> – Engine-ECU –
ENGINE-ECU REMOVAL AND INSTALLATION).
4.Resistance measurement at joint connector (CAN2)
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect joint connector (CAN2) connector.
Check the harness connector side.
Check resistance between joint connector (CAN2) connector terminals.
<LHD>
Joint connector (CAN2) | Joint connector (CAN2) | Resistance |
Connector | Terminal | Connector | Terminal |
A-105 | 4 | A-105 | 15 | 1 kΩ or more |
<RHD>
Joint connector (CAN2) | Joint connector (CAN2) | Resistance |
Connector | Terminal | Connector | Terminal |
A-105 | 2 | A-105 | 13 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
5.Resistance measurement at NOx sensor No.1 connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Check the equipment side.
Check resistance between NOx sensor No. 1 connector terminals.
NOx sensor No. 1 | NOx sensor No. 1 | Resistance |
Connector | Terminal | Connector | Terminal |
A-128 | 4 | A-128 | 3 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
Repair the wiring harness between joint connector (CAN2) and NOx sensor No. 1 connector.
NO <Less than 1 kΩ>
6.Resistance measurement at joint connector (CAN2)
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect joint connector (CAN2) connector.
Check the harness connector side.
Check resistance between joint connector (CAN2) connector terminals.
<LHD>
Joint connector (CAN2) | Joint connector (CAN2) | Resistance |
Connector | Terminal | Connector | Terminal |
A-105 | 5 | A-105 | 16 | 1 kΩ or more |
<RHD>
Joint connector (CAN2) | Joint connector (CAN2) | Resistance |
Connector | Terminal | Connector | Terminal |
A-105 | 1 | A-105 | 12 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
7.Connector check: joint connector
CAUTION:
The strand end of the twist wire should be within 10 cm from the connector (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When checking the joint connector, ensure that its wiring harness side and its short pins are not damaged.
Is the check result normal?
YES
Repair the wiring harness between joint connector (CAN2) and joint connectorr.
NO
Repair a defective connector or replace the joint connector.
8.Resistance measurement at joint connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect joint connector connector.
Check the harness connector side.
Check resistance between joint connector connector terminals.
Joint connector (24) | Joint connector (24) | Resistance |
Connector | Terminal | Connector | Terminal |
G-46 | 3 | G-46 | 2 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
9.Resistance measurement at NOx sensor No. 3 connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Check the equipment side.
Check resistance between NOx sensor No. 3 connector terminals.
NOx sensor No. 3 | NOx sensor No. 3 | Resistance |
Connector | Terminal | Connector | Terminal |
G-47 | 4 | G-47 | 3 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
Repair the wiring harness between joint connector and NOx sensor No. 3 connector.
NO <Less than 1 kΩ>
10.Resistance measurement at joint connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect joint connector connector.
Check the harness connector side.
Check resistance between joint connector connector terminals.
Joint connector (24) | Joint connector (24) | Resistance |
Connector | Terminal | Connector | Terminal |
G-46 | 4 | G-46 | 1 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
NO <Less than 1 kΩ>
11.Resistance measurement at PM sensor connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Check the equipment side.
Check resistance between PM sensor connector terminals.
PM sensor | PM sensor | Resistance |
Connector | Terminal | Connector | Terminal |
G-45 | 3 | G-45 | 2 | 1 kΩ or more |
Is the check result normal?
YES <1 kΩ or more>
Repair the wiring harness between joint connector and PM sensor connector.
NO <Less than 1 kΩ>
12.Resistance measurement at joint connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
The test wiring harness should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
When measuring the resistance, disconnect the negative battery terminal (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Turn the ignition switch to the "LOCK" (OFF) position.
Ensure that the negative battery terminal is disconnected.
Disconnect joint connector connector.
Check the harness connector side.
Check resistance between joint connector connector terminals.
Joint connector (24) | Joint connector (24) | Resistance |
Connector | Terminal | Connector | Terminal |
G-46 | 8 | G-46 | 5 | 120 ± 20 Ω |
Is the check result normal?
YES <Within 120 ± 20 Ω>
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident –
INTERMITTENT INCIDENT).
NO <Not within 120 ± 20 Ω>
13.Resistance measurement at DCU connector
CAUTION:
A digital multimeter should be used (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Strictly observe the specified wiring harness repair procedure (For details refer to Electrical & Power Control – Controller Area Network (CAN) –
SERVICE PRECAUTIONS).
Check the equipment side.
Check resistance between DCU connector terminals.
DCU | DCU | Resistance |
Connector | Terminal | Connector | Terminal |
A-129 | 87 | A-129 | 65 | 120 ± 20 Ω |
Is the check result normal?
YES <Within 120 ± 20 Ω>
Repair the wiring harness between joint connector and DCU connector.
NO <Not within 120 ± 20 Ω>
Check the DCU connector, and repair if necessary. If the DCU connector is in good condition, disconnect the DCU connector, then reconnect it securely.