IDLE SPEED CHECK <EURO 5B OR EURO 6B>N502640200000I00ENG
Before inspection, set the vehicle to the pre-inspection condition.
Turn the ignition switch to the "LOCK" (OFF) position and then connect the M.U.T.-III SE to the diagnosis connector (Refer to General Information – General – Basic Inspection – M.U.T.-III SE Checking System –
HOW TO USE DIAGNOSIS ITEMS).
Set the timing light to the terminal No. 3 power supply line (white) of the ignition coil No. 1.
Start the engine and let it run at idle.
Check that ignition timing is at the standard value.
Standard value: approximately 10° BTDC

NOTE:
The ignition timing may fluctuate within ± 7°. This is normal.
In higher altitude, the ignition timing is more advanced than the standard value by approximately 5°.
Wait till approximately 1 minute passes after the engine started, and check the ignition timing when the engine stabilized.
Check the idle speed.
Standard value: 720 ± 100 r/min

NOTE:
The idle speed is controlled automatically by the idle speed control system.
When using the M.U.T.-III SE, select data list item No. 40 and take a reading of the idle speed.
If the idle speed is outside the standard value, inspect the MPI system (Refer to Engine – Multipoint Fuel Injection (MPI) <4G6> – Troubleshooting –
INSPECTION CHART FOR TROUBLE SYMPTOMS).
Turn the ignition switch to the "LOCK" (OFF) position and then disconnect the M.U.T.-III SE.