2.Check of short to power supply circuit in power supply line between relay control unit (built-in engine control relay) connector and oxygen sensor (front) connector
Turn the ignition switch to the "LOCK" (OFF) position.
Disconnect the oxygen sensor (front) harness connector and relay control unit (built-in engine control relay) harness connector.
Turn the ignition switch to the "ON" position.
Measure the voltage between the oxygen sensor (front) harness connector and body earth. (Short to power supply circuit check)
Repair or replace the connector, or repair the harness between the oxygen sensor (front) harness connector and relay control unit (built-in engine control relay) harness connector.
3.Check of short to power supply circuit in output line between oxygen sensor (front) connector and engine-ECU connector
Turn the ignition switch to the "LOCK" (OFF) position.
Disconnect the engine-ECU harness connector and oxygen sensor (front) harness connector.
Turn the ignition switch to the "ON" position.
Measure the voltage between the oxygen sensor (front) harness connector and body earth. (Short to power supply circuit check)
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT)
BookmarkedToo many bookmarks. Please delete and bookmark again.