(+) | (-) | Voltage | |
Manifold absolute pressure sensor harness connector | |||
Connector | Terminal | ||
B-122 | 3 | Body earth | 4.9 – 5.1 V |
Manifold absolute pressure sensor harness connector | Engine-ECU harness connector | Continuity | ||
Connector | Terminal | Connector | Terminal | |
B-122 | 3 | B-38 | 31 | Continuity exists (2 Ω or less) |
Manifold absolute pressure sensor harness connector | – | Continuity | ||
Connector | Terminal | |||
B-122 | 3 | Body earth | No continuity | |
Manifold absolute pressure sensor harness connector | – | Continuity | ||
Connector | Terminal | |||
B-122 | 3 | Other terminal | No continuity | |
(+) | (-) | Voltage | ||
Manifold absolute pressure sensor harness connector | ||||
Connector | Terminal | |||
B-122 | 3 | Body earth | 1 V or less | |
Manifold absolute pressure sensor harness connector | Engine-ECU harness connector | Condition | ||
Connector | Terminal | Connector | Terminal | |
B-122 | 3 | B-38 | 31 | No damage |
(+) | (-) | Voltage | |
Manifold absolute pressure sensor harness connector | |||
Connector | Terminal | ||
B-122 | 1 | Body earth | Altitude 0 m: 3.8 – 4.2 V Altitude 600 m: 3.5 – 3.9 V Altitude 1,200 m: 3.3 – 3.7 V Altitude 1,800 m: 3.0 – 3.4 V |
Manifold absolute pressure sensor harness connector | – | Continuity | ||
Connector | Terminal | |||
B-122 | 1 | Body earth | No continuity | |
Manifold absolute pressure sensor harness connector | – | Continuity | ||
Connector | Terminal | |||
B-122 | 1 | Other terminal | No continuity | |
(+) | (-) | Voltage | ||
Manifold absolute pressure sensor harness connector | ||||
Connector | Terminal | |||
B-122 | 1 | Body earth | 1 V or less | |
Manifold absolute pressure sensor harness connector | Engine-ECU harness connector | Condition | ||
Connector | Terminal | Connector | Terminal | |
B-122 | 1 | B-38 | 42 | No damage |