Item No. | M.U.T.-III SE display | Drive contents | Inspection conditions | Normal condition |
10 | Injection cut | Cut off No. 1 fuel injector. | Engine: After warm-up, idle operation (Cut off fuel injectors sequentially to check for a cylinder that does not change engine in idle status) | Engine is changed (becomes unstable or stalled) |
Cut off No. 2 fuel injector. | ||||
Cut off No. 3 fuel injector. | ||||
Cut off No. 4 fuel injector. | ||||
20 | Fuel pump | Drive fuel pump to circulate fuel. |
| Operating noise audible |
30 | Purge control solenoid valve | Switch solenoid valve from OFF to ON. | Ignition switch: "ON" | When the valve is actuated, operating noise is audible |
40 | IG 5 BTDC | Fix the ignition timing to 5° BTDC. | Ignition switch: "ON" | Fix the ignition timing to 5° BTDC. |
50 | Cooling fan | Drive A/C condenser fan motor. | Ignition switch: "ON" | A/C condenser fan motor rotates. |
Item No. | M.U.T.-III SE display | Content |
1 | Learned value reset | Initialise the learning value in MPI enigne. |