A/T-ECU | Condition | Resistance | |
Connector | Terminal | ||
G-38 | 27 – 28 | A/T fluid temperature: 10°C | 5.63 – 7.30 kΩ |
A/T fluid temperature: 25°C | 3.5 kΩ (reference value) | ||
A/T fluid temperature: 110°C | 0.23 – 0.27 kΩ | ||
A/T fluid temperature: 145°C | 0.10 – 0.12 kΩ | ||
A/T fluid temperature: 150°C | 0.09 kΩ (minimum) | ||
A/T-ECU | A/T control solenoid valve assembly | Continuity | ||
Connector | Terminal | Connector | Terminal | |
G-38 | 27 | G-42 | 6 | Existed (2 Ω or less) |
28 | 5 | |||