Symptom | Corresponding malfunction part | Check item/Reference | |
Air conditioning system does not activate. Fail-safe does not activate. |
| Check A/C-ECU power supply and earth circuits. | |
Air conditioning cannot be controlled. |
| Check A/C controller assembly power supply and earth circuits. | |
Discharge air temperature does not change. | Air mixing damper control motor system installation condition | Check air mixing damper control motor system is properly installed. | |
Air outlet does not change. | Mode selection damper installation condition | Check mode selection damper is properly installed. | |
Air inlet does not change. | Outside/Inside air selection damper installation condition | Check outside/Inside air selection damper is properly installed. | |
Blower motor does not operates or operation speed is not normal. |
| Check blower motor circuits. Refer to Diagnosis Procedure: Blower motor. | |
A/C compressor does not operate. |
| ||
|
|
| |
|
| ||
Noise is heard when the air conditioning operates. | During A/C compressor operation | Cooler cycle | Symptom table for noise Refer to NOISE SYMPTOM TABLE. |
During blower motor operation |
| Check blower motor. Refer to Component Inspection (Blower motor)BLOWER MOTOR INSPECTION. | |