HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - DIAGNOSIS CODE PROCEDURES - B24C6-12 Blower control duty input (short circuit)
Diagnosis Procedure: B24C6-12
N509002190000600ENG
1.BLOWER MOTOR CONTROL SIGNAL CHECK
  1. Ignition switch ON.
  2. Check duty ratios between power transistor harness connector and body earth by using an oscilloscope.
    (+)
    (−)
    Condition
    Output waveform
    Power transistor
    Connector
    Terminal
    C-31
    4
    Body earth
    Blower motor: OFF
    10.5 – 16 V
    Blower motor: 1st speed (manual)
    Blower motor: 7th speed (manual)
Is the inspection result normal?
YES
NO
2.CHECK BLOWER MOTOR CONTROL SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY
  1. Ignition switch ON.
  2. Disconnect power transistor connector and front blower motor connector.
  3. Check continuity between power transistor harness connector and blower motor harness connector.
    Power transistor
    Blower motor
    Voltage
    Connector
    Terminal
    Connector
    Terminal
    C-31
    1
    C-32
    2
    Not existed
Is the inspection result normal?
YES
NO
Repair harnesses or connector.
BookmarkedToo many bookmarks.
Please delete and bookmark again.