1.CHECK FUSE
Ignition switch "LOCK" (OFF) position.
Check that the following fusible link are not blown (open).
Unit | Location | Fusible link No. | Capacity |
Blower motor | Fuse block (J/B) | 63 | 40A |
Is the fuses blown (open)?
YES
Replace the blown (open) fusible link after repairing the affected circuit if a fusible link are blown (open).
NO
2.CHECK BLOWER MOTOR POWER SUPPLY
Disconnect the blower motor connector.
Ignition switch ON.
Check voltage between blower motor harness connector and body earth.
(+) | (−) | Voltage |
Blower motor |
Connector | Terminal |
C-32 | 1 | Body earth | Battery voltage |
Is the inspection result normal?
YES
NO
3.CHECK BLOWER MOTOR POWER SUPPLY CIRCUIT FOR OPEN
Ignition switch "LOCK" (OFF) position.
Disconnect fuse block (J/B) harness connector.
Check continuity between fuse block (J/B) harness connector and blower motor harness connector.
Fuse block (J/B) | Blower motor | Continuity |
Connector | Terminal | Connector | Terminal |
C-307 | 1 | C-32 | 1 | Existed |
Is the inspection result normal?
YES
Repair the blower motor power supply circuit.
NO
Repair the harnesses or connectors.
4.CHECK BLOWER MOTOR CONTROL SIGNAL CIRCUIT FOR OPEN
Ignition switch "LOCK" (OFF) position.
Disconnect blower motor connector and power transistor connector.
Check continuity between blower motor harness connector and A/C fan control resistor harness connector.
Blower motor | A/C fan control resistor | Continuity |
Connector | Terminal | Connector | Terminal |
C-32 | 2 | C-30 | 4 | Existed |
Is the inspection result normal?
YES
NO
Repair the harnesses or connectors.
5.REPLACE BLOWER MOTOR
Ignition switch ON.
Change fan speed from 1st – 7th, and check that blower motor operates normally.
Is the inspection result normal?
YES
NO