HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - SYMPTOM PROCEDURES - AIR VOLUME OF THE REAR CIRCULATOR CAN NOT BE CHANGED. (FAN MORTOR WORKS)
Diagnosis Procedure: Air volume of the rear circulator can not be changed. (Fan mortor works)
N509002390000100ENG
1.CHECK REAR CIRCULATOR CONTROL PANEL CONNECTOR AND REAR CIRCULATOR CONNECTOR FOR OPEN AND SHORT
  • Check the continuity between the rear circulator control panel connector and rear circulator connector.
    Rear circulator control panel
    Rear circulator
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    E-05
    4
    E-08
    2
    Existed
    9
    1
    Existed
  • Check the continuity between the rear circulator control panel connector terminals.
    Rear circulator control panel
    Continuity
    Connector
    Terminal
    E-05
    4
    9
    Not existed
Is the inspection result normal?
YES
NO
Repair the connector(s) or wiring harness.
2.RETEST THE SYSTEM
Is the inspection result normal?
YES
To check malfunction symptom before repair: Refer to General information - General - Basic inspection - Service information for electrical incident - INTERMITTENT INCIDENT.
NO
Replace the rear circulator control panel (refer to REAR CIRCULATOR CONTROL PANEL REMOVAL AND INSTALLATION).