HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - DIAGNOSIS CODE PROCEDURES - B24DE-15 Ionizer supply (open circuit)
DTC Description: B24DE-15
N509005810000200ENG
DTC DETECTION LOGIC
DTC No.
M.U.T.-III SE screen terms
(Trouble diagnosis content)
DTC detection condition
B24DE-15
Ionizer supply (open circuit)
(Ion generator)
Diagnosis condition
Ignition switch "ON" and blower motor ON.
Signal (Terminal)
Ion generator power supply signal
Threshold
Detects a current value of 20 mA or more does not flow in ion generator power supply signal
Diagnosis delay time
1 second or less
POSSIBLE CAUSE
Ion generator
FAIL-SAFE
—
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
With M.U.T.-III SE
  1. Turn the ignition switch to the "ON" position.
  2. Set the air volume of the blower motor to except OFF, and wait at least 10 seconds.
  3. Select “Self-diagnosis” of “HVAC” using M.U.T.-III SE.
  4. Check DTC.
Is DTC detected?
YES
NO-1
To check malfunction symptom before repair: Refer to General information - General - Basic inspection - Service information for electrical incident - INTERMITTENT INCIDENT.
NO-2
Confirmation after repair: INSPECTION END
BookmarkedToo many bookmarks.
Please delete and bookmark again.