ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - HEADLAMP - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURE - HEADLAMP CIRCUIT RH
Diagnosis Procedure: Headlamp circuit RH <Vehicles with halogen type headlamp>
N514190570000200ENG
1.CHECK HEADLAMP RH POWER SUPPLY
  1. Disconnect Headlamp RH connector
  2. Check voltage between headlamp RH harness connector and body earth.
    (+)
    (-)
    Voltage
    Headlamp LH
    Connector
    Terminal
    HI
    A-51
    4
    Body earth
    Battery voltage
    LO
    2
Is the inspection result normal?
YES
NO
Repair or replace harness.
2.CHECK HEADLAMP RH EARTH CIRCUIT
Check continuity between headlamp RH harness connector and body earth.
Headlamp RH
–
Continuity
Connector
Terminal
A-51
3
Body earth
Existed
Is the inspection result normal?
YES
NO
Repair or replace harness.
3.CHECK HEADLAMP RH CONTROL SIGNAL
  1. Turn the ignition switch ON.
  2. Check voltage between headlamp RH harness connector and body earth.
    (+)
    (-)
    Voltage
    Headlamp LH
    Connector
    Terminal
    HI
    A-51
    4
    Body earth
    6 – 16 V
    LO
    2
Is the inspection result normal?
YES
Replace headlamp RH. Refer to HEADLAMP REMOVAL AND INSTALLATION.
NO
4.CHECK HEADLAMP RH CONTROL SIGNAL CIRCUIT
  1. Turn the ignition switch OFF.
  2. Disconnect relay control unit connector.
  3. Check continuity between headlamp RH harness connector and relay control unit harness connector.
    Headlamp RH
    Relay control unit
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    E405
    2
    E218
    6
    Existed
    Headlamp LH
    Relay control unit
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    HI
    A-51
    4
    A-23
    6
    Existed
    LO
    2
    A-21
Is the inspection result normal?
YES
Replace relay control unit. Refer to RELAY CONTROL UNIT REMOVAL AND INSTALLATION.
NO
Repair or replace harness.
BookmarkedToo many bookmarks.