When float of the fuel gauge unit is in stopper positions "1" and "0", ensure that resistance between the fuel gauge unit terminal and earth terminal is within the standard value.
Standard value:
Float position
Gauge resistance value (Ω)
Stopper position "1"
91 ± 3.0
Stopper position "0"
283 ± 5.0
When the float is moved slowly between stopper positions "F" and "E", ensure that the resistance is smoothly changing.