ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - MULTI AROUND MONITOR - TROUBLESHOOTING
DIAGNOSIS TROUBLESHOOTING FLOW
N514290040000100ENG
OVERALL SEQUENCE
DETAILED FLOW
1.INTERVIEW AND SYMPTOM CONFIRMATION
Check the malfunction symptoms by performing the following items.
  • Interview the customer to obtain the malfunction information (conditions and environment when the malfunction occurred).
  • Check the symptom.
Is the occurred symptom malfunction?
YES
NO
INSPECTION END
2.DIAGNOSIS WITH M.U.T.-III SE
  1. Connect M.U.T.-III SE and perform a self-diagnosis for “Multi Around Monitor”. Refer to DIAGNOSIS FUNCTION.
    NOTE:
    Skip to step 4 of the diagnosis procedure if “Multi Around Monitor” is not displayed.
  2. When DTC is detected, follow the instructions below:
    • Record DTC and Freeze Frame Data.
Is DTC displayed?
YES
NO
3.TROUBLE DIAGNOSIS FOR DTC
  1. Check the DTC indicated in the “Self-diagnosis”.
  2. Perform the relevant diagnosis referring to the DTC Index. Refer to DIAGNOSIS CODE CHART.
4.TROUBLE DIAGNOSIS FOR SYMPTOMS
Perform the relevant diagnosis referring to the diagnosis chart by symptom. Refer to SYMPTOM CHART.
5.ERROR PART REPAIR
  1. Repair or replace the identified malfunctioning parts.
  2. Perform a self-diagnosis for “Multi Around Monitor” with M.U.T.-III SE.
    NOTE:
    Erase the stored self-diagnosis results after repairing or replacing the relevant components if any DTC has been indicated in the “Self-diagnosis”.
  3. Check that the symptom does not occur.
Does the symptom occur?
YES
NO
INSPECTION END