ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - ETACS - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - B2C95-01 Combination switch
Diagnosis Procedure: B2C95-01
N514311310000100ENG
1.CHECK COLUMN SWITCH CIRCUIT FOR SHORT TO BATTERY
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Disconnect column switch connector and ETACS-ECU connectors.
  3. Check voltage between column switch harness connector and body earth.
    (+)
    (-)
    Voltage
    (Approx.)
    Column switch
    Connector
    Terminal
    C-201
    1
    Body earth
    0 V
    3
    4
    6
    8
    13
    12
    7
    15
    10
    5
    2
Is the inspection result normal?
YES
NO
Repair or replace harness or connectors.
2.PERFORM "DATA LIST" OF ETACS-ECU
With M.U.T.-III SE
  1. Connect column switch connector and ETACS-ECU connectors.
  2. Perform "Data List" of ETACS-ECU to check for any malfunctioning item. Refer to Combination switch symptom table.
Is the inspection result normal?
YES
Replace column switch. Refer to COLUMN SWITCH REMOVAL AND INSTALLATION.
NO
Replace ETACS-ECU. Refer to ETACS-ECU REMOVAL AND INSTALLATION.