ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - ON-VEHICLE SERVICE
UREA LINE TUBE HEATER CHECK
N502630650000800ENG
Since the urea line tube heaters are built into the urea line tubes A, B and C, check the heaters by the following procedures.
Urea Line Tube Location
Check Procedure
Remove the engine room under cover front (Refer to Body Exterior, Doors, Roof & Vehicle Security – Exterior – UNDER COVER REMOVAL AND INSTALLATION).
Disconnect the connection of the urea line tube A heater connector and urea line tube B heater connector.
Measure the resistance between urea line tube A heater connector terminals.
Standard value (Only urea line tube A): 0.44 to 0.55 Ω (at 20°C)
  • If the resistance is within the standard value, go to step 4.
  • If the resistance deviates from the standard value, replace the urea line tube A, then go to step 4.
Connect the urea line tube A heater connector and urea line tube B heater connector, then disconnect the connection of the urea line tube B heater connector and urea line tube C heater connector.
Measure the resistance between urea line tube B heater connector terminals.
Standard value (Urea line tube A and B heater connectors connected): 0.77 to 0.97 Ω (at 20°C)
  • If the resistance is within the standard value, go to step 6.
  • If the resistance deviates from the standard value, replace the urea line tube B, then go to step 6.
Remove the urea tank protector (front side and under) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
Connect the urea line tube B heater connector and urea line tube C heater connector, then disconnect the urea line tube C heater connector (urea tank side).
Measure the resistance between urea line tube C heater connector (urea tank side) terminals.
Standard value (Urea line tube A, B and C heater connectors connected): 0.44 to 0.55 Ω (at 20°C)
  • If the resistance is within the standard value, go to step 9.
  • If the resistance deviates from the standard value, replace the urea line tube C, then go to step 9.
Connect the urea line tube C heater connector (urea tank side).
Install the urea tank protector (front side and under) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).