Diagnosis Code No. | M.U.T.-III SE Screen Item [Diagnosis item] | Diagnosis Code Detection Condition | |
P203A-2A | Reductant level sensor A [Urea tank level sensor stuck] | Diagnosis condition |
|
Signal (terminal) | Urea level sensor | ||
Threshold | The state that there is no change in the urea tank level (below 1 mm) during acceleration and deceleration is detected 5 times or more (approximately 5 minutes). | ||
Diagnosis delay time | None. | ||