1.Visually check urea tank assembly
Check the urea tank assembly for damage and AdBlue® leakage.
Is the check results normal?
YES
NO
2.AdBlue® replenishment check
Check the amount and condition of AdBlue®.
Are the quantity and condition of AdBlue® normal?
YES
NO
3.Check other diagnosis code
Check whether the following diagnosis codes are set.
P202A-11: Reductant tank heater
P202A-12: Reductant tank heater
P202A-13: Reductant tank heater
P202A-92: Urea Tank Heater Control Circuit Performance
P203A-01: Reductant level sensor A
P203A-11: Reductant level sensor A
P203A-12: Reductant level sensor A
P205A-11: Reductant tank temperature sensor
P205A-12: Reductant tank temperature sensor
P205A-1C: Urea Tank Temperature Sensor Circuit Range/Performance
P206A-11: Reductant quality sensor
P206A-12: Reductant quality sensor
P206A-1F: Reductant quality sensor
P33FF-1C: Power supply error(urea tank temperature sensor)
U0619-00: Lost communication(reductant level sensor A)
U1353-81: SENT communication error(urea tank temperature sensor)
Is any diagnosis code set?
YES
NO
4.Check data list
Is the urea tank temperature above 1 °C?
YES
NO
5.Check data list
Is the check results normal?
YES
NO
6.Diagnosis code recheck after erasing diagnosis code
Is diagnosis code No. P203A-2A set?
YES
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident –
INTERMITTENT INCIDENT).