Item No. | Inspection Item | Inspection condition | Normal condition | |
1 | Protection control operating state(urea injector 1) |
| OFF | |
During high exhaust gas temperature condition. | ON | |||
2 | Urea injector 1 tip temperature | Engine: Idle operation | Ambient temperature to 120°C | |
15 | SCR system condition | During the initial check immediately after the startup. | Initial state | |
Under stand-by status after the initial check is completed. The pressure control is not started (waiting for the exhaust gas temperature to rise, defrosting the urea water, etc.). | No pressure control | |||
During pressure build-up. | Pressure build-up | |||
During pressure control. | Pressure build-up completed | |||
During pressure reduction control. | Decompression state | |||
During pressure build-up. | Air venting condition | |||
During first filling. | Initial replenishment state | |||
The AdBlue® is being returned. (finished to be returned) | Sucking back completed state | |||
The AdBlue® is being returned. | Sucking back state | |||
Just IG-ON | Ignition ON state | |||
16 | SCR system sub condition | Other than below. | No sub state | |
Before pressure build-up. | Pressure build-up preparation | |||
During pressure build-up. | Ventilation | |||
During pressure reduction | Normal decompression | |||
Decompression injector 1 open | ||||
During pressure sensor replacement | Pressure sensor replacement | |||
During pressure reduction | Decompression injector 2 open | |||
During air purging | System circulation | |||
After finishing first filling | Successful initial filling | |||
After finishing pressure reduction | Initial decompression state | |||
During pressure reduction | Decompressed state | |||
During pump valve open | Pump valve open state | |||
During urea defrosting | Heat A(Urea tank-Piping) | |||
Defrost confirm supply pump | ||||
Thaw confirm suction pump | ||||
Heat B(hydro connector) | ||||
Defrost confirm hydro connector | ||||
Urea pump re thawing | ||||
Defrost confirm urea pump | ||||
19 | Urea backflow pump operating status | Other than below. | Deactivated | |
Low temperature condition (Ambient temperature or Urea tank temperature is below –7°C) | Freezing and defrosting | |||
| Pump active | |||
Low temperature condition (Ambient temperature or Urea tank temperature is below –7°C) | Anti-freeze heating | |||
When the ignition switch is turned to the "LOCK" (OFF) position from the "ON" position. | Backflow pump passage fully open | |||
20 | NOx sensor 1 signal enable flag | Other than below. | OFF | |
Engine: After warm-up, idle operation (After the dew point is reached). | ON | |||
21 | NOx sensor 3 signal enable flag | Other than below. | OFF | |
Engine: After warm-up, idle operation (After the dew point is reached). | ON | |||
22 | Ignition switch | Ignition switch: "LOCK" (OFF) position | OFF | |
Ignition switch: "ON" position | ON | |||
23 | PM sensor temperature | Engine: Idling after warming up the engine | When the exhaust gas temperature at the down stream SDPF is 150°C. | 150°C |
When the exhaust gas temperature at the downstream SDPF is 300°C. | 300°C | |||
When the exhaust gas temperature at the downstream SDPF is 450°C. | 450°C | |||
When the exhaust gas temperature at the downstream SDPF is 600°C. | 600°C | |||
When the exhaust gas temperature at the downstream SDPF is 750°C. | 750°C | |||
24 | Urea tank frozen state | Other than below | Not frozen | |
Ambient temperature or Urea tank temperature ≦ –7°C | Temperature retention mode | |||
Suspected tank freeze | ||||
Tank freeze detection | ||||
– | NONE | |||
27 | NOx sensor 1 heater operating | Other than below. | OFF | |
Engine: After warm-up, idle operation (After the dew point is reached). | ON | |||
28 | NOx sensor 3 heater operating | Other than below. | OFF | |
Engine: After warm-up, idle operation (After the dew point is reached). | ON | |||
29 | PM sensor heater operating | Other than below. | OFF | |
Engine: After warm-up, idle operation (After the dew point is reached). | ON | |||
36 | Service execution status | Other than below. | Not implemented | |
During "SCR system test" | Completed | |||
Suspend | ||||
Running | ||||
37 | Initial filling interruption | During "SCR system test" | Being implemented | |
When "SCR system test" is failed | DTC detected | |||
Vehicle speed | ||||
Engine speed | ||||
Exhaust gas temperature high | ||||
Tank temperature drop | ||||
Urea tank level low | ||||
Battery voltage drop | ||||
Initial filling completed | ||||
Out of executable status range | ||||
Exceeded No. implementations | ||||
Suspended by IGN OFF | ||||
38 | Urea pressure feed interruption | During "SCR system test" | Being implemented | |
When "SCR system test" is failed | DTC detected | |||
Vehicle speed | ||||
Engine speed | ||||
Exhaust gas temperature high | ||||
Tank temperature drop | ||||
Urea tank level low | ||||
Battery voltage drop | ||||
Initial filling completed | ||||
Out of executable status range | ||||
Exceeded No. implementations | ||||
39 | Decompression interruption | During "SCR system test" | Being implemented | |
When "SCR system test" is failed | DTC detected | |||
Vehicle speed | ||||
Engine speed | ||||
Exhaust gas temperature high | ||||
Tank temperature drop | ||||
Urea tank level low | ||||
Battery voltage drop | ||||
Initial filling completed | ||||
Out of executable status range | ||||
40 | Service status | Other than below. | Not implemented | |
During "SCR system test" | Initial filling completed | |||
Ready for pressure | ||||
Decompression completed | ||||
42 | Battery voltage | Ignition switch: "ON" position | Battery voltage | |
47 | Tank defrosting judgment | Engine: Idle operation (Urea tank not frozen) | OFF | |
Engine: Idle operation (Urea tank frozen) | ON | |||
49 | Exhaust gas temperature upstream SCR catalyst 1 | Engine: Idle operation after warm-up | When the exhaust gas temperature is 150°C. | 150°C |
When the exhaust gas temperature is 300°C. | 300°C | |||
When the exhaust gas temperature is 450°C. | 450°C | |||
When the exhaust gas temperature is 600°C. | 600°C | |||
When the exhaust gas temperature is 750°C. | 750°C | |||
51 | Urea tank heater status | Other than below. | OFF | |
| ON | |||
53 | Urea water first filling success | After DCU replacement | OFF | |
Other than above | ON | |||
56 | Vehicle speed | Running at 40 km/h. | Approximately 40 km/h | |
57 | Engine operation status | – | STANDBY | |
Ignition switch: "ON" position | READY | |||
– | CRANKING | |||
Engine: Idle operation | RUNNING | |||
– | STOPPING | |||
STOPPED | ||||
58 | Urea hose heater operate state | Other than below. | OFF | |
| ON | |||
59 | Urea refill event is detected | Ignition switch: "ON" position | OFF | |
Ignition switch: "ON" position (Refill urea is detected) | ON | |||
60 | Backflow pump operating state | Other than below. | OFF | |
| ON | |||
61 | Supply pump operating state | Other than below. | OFF | |
| ON | |||
65 | PM sensor detection time ratio | Engine is running after PM sensor is activated (after data list item No. 100: PM sensor status has changed to "Measurement"). | 0.000 to 1.000 | |
66 | Result for defect detection DPF | When diagnosis code No. P2002-00: DPF Flow Resistance Below Limit is detected | Less than 1.0 | |
68 | PM sensor status information(Dew point end reached) | Other than below. | OFF | |
Engine: After warm-up, idle operation (After the dew point is reached). | ON | |||
69 | Engine speed |
| Compare engine speed on tachometer with the value displayed on M.U.T.-III SE. | Matched |
| When the engine coolant temperature is –20°C. | 840 to 900 r/min | ||
When the engine coolant temperature is 0°C. | 770 to 830 r/min | |||
When the engine coolant temperature is 25°C. | 690 to 750 r/min | |||
When the engine coolant temperature is 40°C. | ||||
When the engine coolant temperature is 80°C. | ||||
70 | Coolant temperature | Ignition switch: "ON" position or Engine: Running | When the engine coolant temperature is –20°C. | –20°C |
When the engine coolant temperature is 0°C. | 0°C | |||
When the engine coolant temperature is 25°C. | 25°C | |||
When the engine coolant temperature is 40°C. | 40°C | |||
When the engine coolant temperature is 80°C. | 80°C | |||
73 | DPF regeneration mode | Other than below. | OFF | |
During DPF regeneration | ON | |||
74 | Fuel cut | Other than below. | OFF | |
Driving: Accel pedal released during vehicle running | ON | |||
75 | Boost pressure | Ignition switch: "ON" position | Altitude: 0 m | 1,010 hPa |
Altitude: 600 m | 950 hPa | |||
Altitude: 1,200 m | 880 hPa | |||
Altitude: 1,800 m | 810 hPa | |||
| When engine is suddenly raced. | The value changes according to the pressure inside the inlet manifold. | ||
76 | Air flow sensor value | Ignition switch: "ON" position | 0 kg/h | |
Engine: Running | 0 kg/h or more | |||
77 | EGR rate | Engine: Running | 0 to 100 | |
78 | EGR valve opening degree | Ignition switch: "ON" position or Engine: Running | 0 to 100 % | |
81 | Vehicle acceleration(front/rear G) | Vehicle stopped (level) | –0.4 to 0.4 m/s2 | |
Running | –9.8 to 9.8 m/s2 | |||
82 | Vehicle acceleration(lateral G) | Vehicle stopped (level) | –1.1 to 1.1 m/s2 | |
Running | –9.8 to 9.8 m/s2 | |||
84 | Gear position <A/T> | Selector lever: "P" or "N" position | N or P | |
Selector lever: Sport mode | Driving at a constant speed of 10 km/h in 1st | 1st | ||
Driving at a constant speed of 20 km/h in 2nd | 2nd | |||
Driving at a constant speed of 40 km/h in 3rd | 3rd | |||
Driving at a constant speed of 60 km/h in 4th | 4th | |||
Driving at a constant speed of 70 km/h in 5th | 5th | |||
Driving at a constant speed of 80 km/h in 6th | 6th | |||
85 | Accelerator pedal opening degree | Ignition switch: "ON" position | 0 to 100% | |
86 | Brake signal | Ignition switch: "ON" position | Brake pedal: Released | OFF |
Brake pedal: Depressed | ON | |||
87 | Ambient pressure | Ignition switch: "ON" position | Altitude: 0 m | 1,010 hPa |
Altitude: 600 m | 950 hPa | |||
Altitude: 1,200 m | 880 hPa | |||
Altitude: 1,800 m | 810 hPa | |||
88 | Throttle valve opening degree | Ignition switch: "ON" position | 0 to 100% | |
90 | Urea injection control status | Other than below | Stop urea injection | |
Engine: After warm-up, After data list item No. 5:SCR1 catalyst average temperature is reached to 180°C. | Permission for urea injection | |||
During urea dosing limitation is active. | Restricted (NH3 slip) | |||
During DPF regeneration | Stop (DPF regen requirement) | |||
Urea inj permit (regen prog) | ||||
Stop(DPF regen temperature high) | ||||
During urea dosing limitation is active. | Restricted(exh system fail) | |||
Stop (regen required exh fail) | ||||
Restricted (exh fail DPF regen) | ||||
91 | Urea level sensor status | Other than below. | No signal | |
Signal NG(short time) | ||||
Ignition switch: "ON" position (Urea tank level sensor is available) | Signal OK(reception low) | |||
Signal OK(reception medium) | ||||
Signal OK(reception high) | ||||
Signal OK(maximum reception) | ||||
92 | Urea temperature sensor status | Other than below. | Not available | |
Ignition switch: "ON" position (Urea tank temperature sensor is available) | Available | |||
93 | Urea concentration signal status | Other than below. | NG(no signal) | |
NG(sonar low quality) | ||||
NG(sonar low constant) | ||||
Ignition switch: "ON" position (Urea concentration sensor is available) | OK(sonar high quality small) | |||
OK(sonar high quality medium) | ||||
OK(sonar high quality large) | ||||
96 | Urea concentration | Ignition switch: "ON" position | Around 32.5% | |
97 | Duty of electrical water pump | Other than below. | 0% | |
Ignition switch: soon after "LOCK" (OFF) position | 17% | |||
100 | PM sensor status | During PM sensor regeneration | Initialize(Sensor regeneration) | |
Engine: After warm-up, idle operation (After the dew point is reached). | Measurement | |||
Engine is running (Before the dew point is reached). | Sensor not ready | |||
After finishing PM sensor regeneration | Regeneration finished | |||
102 | EGR valve rate | Ignition switch: "ON" position or Engine: Running | 0 to 100% | |
103 | Exhaust gas temperature sensor 1 | Engine: Idle operation after warm-up | When the exhaust gas temperature is 150°C. | 150°C |
When the exhaust gas temperature is 300°C. | 300°C | |||
When the exhaust gas temperature is 450°C. | 450°C | |||
When the exhaust gas temperature is 600°C. | 600°C | |||
When the exhaust gas temperature is 750°C. | 750°C | |||
104 | Exhaust gas temperature sensor 2 | Engine: Idle operation after warm-up | When the exhaust gas temperature is 150°C. | 150°C |
When the exhaust gas temperature is 300°C. | 300°C | |||
When the exhaust gas temperature is 450°C. | 450°C | |||
When the exhaust gas temperature is 600°C. | 600°C | |||
When the exhaust gas temperature is 750°C. | 750°C | |||
105 | Exhaust gas temperature sensor 3 | Engine: Idle operation after warm-up | When the exhaust gas temperature is 150°C. | 150°C |
When the exhaust gas temperature is 300°C. | 300°C | |||
When the exhaust gas temperature is 450°C. | 450°C | |||
When the exhaust gas temperature is 600°C. | 600°C | |||
When the exhaust gas temperature is 750°C. | 750°C | |||
108 | DPF operation status | Other than below. | Normal mode | |
During DPF regeneration | Regeneration mode | |||
Before SCR catalyst warm | SCR Catalyst warm up mode | |||
Item No. | Inspection item | M.U.T.-III SE display descriptions | Standards at each check | Display range, and numeric value |
3 | SCR1 ammonia absorption | Calculated amount of ammonia adsorbed in the main catalytic converter (SCR-DPF) | Engine: Idle operation | 0 g or more |
4 | SCR2 ammonia absorption | Calculated amount of ammonia adsorbed in the catalytic converter (SCR) | Engine: Idle operation | 0 g or more |
5 | SCR1 catalyst average temperature | Main catalytic converter (SCR-DPF) average temperature value calculated from exhaust gas temperature sensor values, etc. | Engine: Idle operation | Ambient temperature to 750°C |
6 | SCR2 catalyst average temperature | Average catalytic converter (SCR) temperature value calculated from exhaust gas temperature sensor value, etc. | Engine: Idle operation | Ambient temperature to 750°C |
7 | Urea consumption rate | Average consumption rate for the last 2,400 km travelled | Engine: Idle operation | 0 to 10 g/km |
8 | Exhaust gas flow rate | Exhaust gas flow values received from the Engine-ECU via CAN communication. | Engine: Idle operation | 0 kg/h or more |
9 | NOx sensor 1 received heat quantity | Value of the heat amount that NOX sensor No. 1 received from the exhaust gases from the start of the engine. | Engine: Idle operation | 0 kJ or more |
10 | NOx sensor 3 received heat quantity | Value of the heat amount that NOX sensor No. 3 received from the exhaust gases from the start of the engine. | Engine: Idle operation | 0 kJ or more |
11 | PM sensor received heat quantity | Value of the heat amount that PM sensor received from the exhaust gases from the start of the engine. | Engine: Idle operation | 0 kJ or more |
12 | NOx sensor 1 heat quantity threshold | Threshold value of the heat amount that NOX sensor No. 1 received from the exhaust gases from the start of the engine. | Engine: Idle operation | 0 kJ or more |
13 | NOx sensor 3 heat quantity threshold | Threshold value of the heat amount that NOX sensor No. 3 received from the exhaust gases from the start of the engine. | Engine: Idle operation | 0 kJ or more |
14 | PM sensor heat quantity threshold | Threshold value of the PM sensor received from the exhaust gases from the start of the engine. | Engine: Idle operation | 0 kJ or more |
17 | Urea tank level | Detected value of urea tank level sensor | Ignition switch: "ON" position | 0 to 160 mm |
18 | Urea injector 1 desired dosing quantity | Indicated injection volume of urea water calculated by the DCU based on NOx emissions | Engine: Idle operation | 0 mg/s or more |
25 | Estimated ammonia concentration downstream SCR1 | Concentration of ammonia flowing out to the downstream of the SCR-DPF in the main catalytic converter (DCU calculated value) | Engine: Idle operation | 0 ppm or more |
26 | Estimated ammonia concentration downstream SCR2 | Concentration of ammonia flowing out to the downstream of the SCR in the catalytic converter (DCU calculated value) | Engine: Idle operation | 0 ppm or more |
30 | Urea tank heater current | Urea tank heater current value when driven | Engine: Idle operation | 0 to 30 A |
31 | Urea tube heater current | Urea tube heater current value when driven | Engine: Idle operation | 0 to 15 A |
32 | Supply pump current value | Supply pump current value when driven | Engine: After warm-up, idle operation | 0 to 3,000 mA |
33 | Back flow pump current value | Back flow pump current value when driven | Engine: After warm-up, idle operation | 0 to 3,000 mA |
34 | Urea total injection quantity 1 | Total amount of urea injection from the condition when the DCU is replaced with a new one. | Engine: Idle operation | 0 to 429,496,729,500 mg |
35 | Total mileage | Total distance travelled by the vehicle from the condition when the DCU is replaced with a new one. | Ignition switch: "ON" position | 0 to 4,294,967,295 m |
41 | Urea tank temperature | Value of the tank temperature sensor on the urea pump | Ignition switch: "ON" position | –40 to 80°C |
43 | Urea tank remaining volume(%) | Remaining urea tank volume (displayed in %) | Ignition switch: "ON" position | 0 to 100 % |
44 | Urea tank remaining volume(L) | Remaining urea tank volume (displayed in litres) | Ignition switch: "ON" position | 0 to 18.47 L |
45 | Urea tank remaining volume(g) | Remaining urea tank volume (displayed in grams) | Ignition switch: "ON" position | 0 to 21,000 g |
46 | Urea tank level sensor(filtered value) | Detected value of urea tank level sensor (filter value) | Ignition switch: "ON" position | 0 to 160 mm |
48 | SCR catalyst efficiency | Value of NOx purification efficiency calculated from NOx sensor No. 1 and NOx sensor No. 3 values. | Engine: Idle operation | 0.0 to 1.0 |
50 | Urea pressure sensor(filtered value) | Detected value of urea pressure sensor (filter value) | Engine: After warm-up, idle operation (Data list item No. 15: SCR system condition = Pressure build-up completed) | 5,000 to 7,000 hPa |
52 | Urea injector 1 drive duty | Urea injector drive duty value | Engine: After warm-up, idle operation | 0 to 100 |
54 | Mileage after DCU replacement | Driving distance since DCU replacement | Ignition switch: "ON" position | 0 to 2,147,483,647 m |
55 | Urea tank level sensor(raw value) | Detected value of urea tank level sensor | Ignition switch: "ON" position | 0 to 160 mm |
62 | NOx sensor 1 detect concentration | NOx concentration detected by NOx sensor No. 1 | Engine: After warm-up | 0 to 33,000 ppm |
63 | NOx sensor 3 detect concentration | NOx concentration detected by NOx sensor No. 3 | Engine: After warm-up | 0 to 33,000 ppm |
64 | Total fuel injection quantity(1 cycle) | Indicates the integrated fuel injection quantity in 1 cycle (pilot injection, pre-injection, main injection, after-injection, post injection). | Engine: Idle operation | 0 to 1,020 mg/hub |
67 | DPF soot deposition | Indicates the DPF soot accumulation. | Ignition switch: "ON" position | 0 to 12.75 g |
71 | Ambient temperature | Indicates the ambient temperature. | Ignition switch: "ON" position | –40 to 80°C |
72 | Target torque | Indicates the target torque. |
| –150 to 500 Nm |
79 | Remaining mile urea refill warning | Distance that can be travelled until the remaining urea water level becomes empty. | Ignition switch: "ON" position | 0 to 17,000 km |
80 | O2 value(NOx sensor 1) | Oxygen concentration detected by NOx sensor No. 1 | Engine: Idle operation [After NOx sensor No. 1 is ON (data list item No. 27: NOx sensor 1 heater operating: ON)] | 0 to 0.21 |
83 | Driving distance after regeneration | Distance travelled since the completion of the last DPF regeneration | Ignition switch: "ON" position | 0 to 2,147,483,647 m |
89 | O2 value(NOx sensor 3) | Oxygen concentration detected by NOx sensor No. 3 | Engine: Idle operation [After NOx sensor No. 3 is ON (data list item No. 28: NOx sensor 3 heater operating: ON)] | 0 to 0.21 |
94 | Urea pressure sensor(filter value) | Detected value of urea pressure sensor (filter value) | Engine: After warm-up, idle operation (Data list item No. 15: SCR system condition = Pressure build-up completed) | 5,000 to 7,000 hPa |
95 | Fuel injection quantity | Indicates the command fuel injection quantity. | Engine: Idle operation | 0 to 120 mg/hub |
98 | SCR1 target ammonia absorption | Target amount of ammonia to be adsorbed by the main catalytic converter (SCR-DPF) | Engine: Idle operation | 0 g or more |
99 | SCR2 target ammonia absorption | Target amount of ammonia to be adsorbed by the catalytic converter (SCR) | Engine: Idle operation | 0 g or more |
101 | PM sensor current | Current value flowing at the electrodes of the PM sensor | Engine: After warm-up | 0 uA or more |
106 | Number of moving detection of urea injector 1 valve | Number of times the valve inside the urea injector is operating correctly. | Engine: Idle operation | 0 count or more |
107 | Urea supply pump current(Pump lift stopped) | Current value detected when the solenoid inside the supply pump reaches the end of its range of motion. | Engine is running (After data list item No. 15: SCR system condition has changed to "pressure build-up"). | 0 mA or more |
109 | Urea consumption error factor | Value indicating the degree of deviation between urea water pump discharge and injection volume. | Engine: Idle operation | 0.69 to 1.35 |