ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING
SPECIAL FUNCTION REFERENCE TABLE
N502634880000G00ENG
NOTE:
The following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to M.U.T.-III SE display items.
ECU INFORMATION
Display the DCU part number.
ACTUATOR TEST
Item No.
M.U.T.-III SE display
Test contents
Inspection conditions
Value to be determined as normal
1
Urea hose heater
Turn the urea feed tube heater ON
  • Ignition switch: "ON" position
  • Vehicle speed: less than 5km/h
Energise the urea feed tube heater for approximately 10 seconds. (Data list item No. 58: Urea hose heater operate state is turned to "ON")
2
Urea tank heater
Turn the urea tank heater ON
  • Ignition switch: "ON" position
  • Vehicle speed: less than 5km/h
Energise the urea tank heater for approximately 10 seconds. (Data list item No. 51: Urea tank heater status is turned to "ON")
3
Urea injector 1 Dosing
Urea injector is driven.
  • Ignition switch: "ON" position
  • Vehicle speed: less than 5km/h
Operating noise is heard. (Out put data list item No. 52: Urea injector 1 drive duty value)
TRANSPORT MODE ACTIVATION
The transport mode activation is a function not to interrupt the SCR system test when the M.U.T.-III SE is disconnected during the test.
If a urea SCR system test is initiated after the trans port mode activation has been executed, it will continue until completion without interruption even when the M.U.T.-III SE is disconnected during the test.
Use this function if another vehicle inspection needs to be carried out during the SCR system test, but the test can be carried out normally without this function as long as the M.U.T.-III SE is connected until completion.
UREA LEVEL/QUALITY SENSOR SONAR TEST
Item No.
M.U.T.-III SE display
Test contents
Inspection conditions
Normal condition
1
Urea level/quality sensor sonar test
Sonar test is forcibly carried out in the sonar diagnosis of urea level sensor or in the sonar diagnosis of urea quality sensor.
Ignition switch: "ON" position
It is normal if the diagnosis code (P203A-1F or P206A-1F) is not detected after the sonar test.
TEST
Item No.
M.U.T.-III SE display
Test contents
Inspection conditions
Normal condition
1
Urea injector 1 Dosing test
Check that the urea water can be injected normally.
  • Ignition switch: "ON" position
  • After item No. 4 "Urea pumping and Dosing test" is performed.
Operating noise is heard. (Out put data list item No. 52: Urea injector 1 drive duty value)
2
Urea line emptying test
Drain urea water from the urea feed tube.
Ignition switch: "ON" position (but do not start the engine)
The back flow pump is activated and the urea water in the urea feed tube is returned to the urea tank.
3
Urea pump first filling test
Draw back and empty the urea water in the urea feed tube (Urea feed tube).
The purpose is to reduce pressure and prevent urea water leakage when disconnecting the urea line (injector and hose). If the pressure remains high, the parts cannot be removed.
Ignition switch: "ON" position (but do not start the engine)
The back flow pump is activated and the urea water in the urea feed tube is returned to the urea tank.
4
Urea pumping and Dosing test
The urea pressure feed pump (Supply pump) is driven to pump urea water from the urea tank to the urea feed tube to boost pressure.
Ignition switch: "ON" position (but do not start the engine)
The supply pump is activated and the urea water in the urea tank is sent to the urea feed tube.
5
Urea SCR system test
The following items are performed in the order below.
  1. Urea pump first filling test
  2. Urea pumping and Dosing test
  3. Urea line emptying test
The air bleeding inside the pump and the pump function check can be performed at the same time.
  • Ignition switch: "ON" position
  • Data list item No. 41: Urea tank temperature is 2°C or more.
  • Data list item No. 46: Urea tank level sensor(filtered value) is 15 mm or more.
  • Data list item No. 15: SCR system condition is "Initial state" or "No pressure control"
It is normal if the entire series of tests is completed.
6
Urea leak test
Raise and hold the urea water pressure and check for pressure drop.
The purpose is to check for urea water leakage from the urea injector and urea feed tube.
Ignition switch: "ON" position (but do not start the engine)
No leakage of urea water from the urea injector and urea feed tube
INITIALIZATION
Item No.
M.U.T.-III SE display
Content
1
SCR Catalyst 1 initialization
After replacement of the main catalytic converter (SCR-DPF), initialise the values related to the SCR-DPF stored in the DCU .
2
NOx sensor 1 initialization
After replacement of NOx sensor No. 1, initialise the values related to NOx sensor No. 1 stored in the DCU.
3
NOx sensor 3 initialization
After replacement of NOx sensor No. 3, initialise the values related to NOx sensor No. 3 stored in the DCU.
4
SCR exhaust temperature sensor initialization
After replacement of the exhaust gas temperature sensor No. X, initialise the values related to exhaust gas temperature sensor No. X stored in the DCU.
5
DCU initialization (without value transfer)
NOTE:
This item is displayed, but is not used.
6
DCU initialization (with value transfer)
7
DOC initialization
After replacement of the main catalytic converter (DOC), initialise the values related to DOC stored in the DCU.
8
DPF initialization
After replacement of the main catalytic converter (DPF), initialise the values related to DPF stored in the DCU.
9
Urea injector 1 initialization
After replacement of the urea injector assembly, initialise the values related to urea injector stored in the DCU.
10
SCR Catalyst 2 initialization
After replacement of the catalytic converter (SCR), initialise the values related to SCR stored in the DCU.
11
Urea tank level update
  • When the urea water is refilled
    NOTE:
    If the refill quantity at one time is 4 litres or more, the AdBlue® remaining amount warning can be turned off without performing the urea tank level reset. The warning can be turned off by performing the following procedure. Stop the vehicle on a level surface, and turn the ignition switch from "LOCK" (OFF) to "ON" (do not start the engine). Then, leave the vehicle for approximately 5 minutes or more.
  • When the urea tank assembly is replaced
  • When the DCU is replaced
RESET
Item No.
M.U.T.-III SE display
Content
1
Urea injector 1 total dosed quantity reset
After replacement of the urea injector assembly, set the value of the total urea injection volume of the urea injector stored by the DCU to 0. (It is not necessary when the DCU is replaced since the total urea injection volume stored in the new DCU is set to 0 by default.)
2
Urea consumption error diagnosis value reset
After detecting an abnormal urea consumption diagnosis (diagnosis code No. P20F4-00 or P20F5-00) and carrying out the troubleshooting, reset the value used as the diagnosis threshold for the abnormal urea consumption diagnosis to its initial value.
BookmarkedToo many bookmarks.