ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - COMBINATION METER - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURES - POWER SUPPLY AND EARTH CIRCUIT
Diagnosis Procedure: Power supply and earth circuit
N514281690000G00ENG
1.CHECK FUSE
Check for blown fuses.
Power source
Fuse No.
Battery
29
Ignition switch ON or START
6
Is the inspection result normal?
YES
NO
Be sure to eliminate cause of malfunction before installing new fuse.
2.CHECK POWER SUPPLY CIRCUIT
Check voltage between combination meter harness connector and body earth.
Terminals
Ignition switch position
Voltage
(Approx.)
(+)
(−)
Combination meter
Body earth
Connector
Terminal
C-11
16
OFF
Battery voltage
15
ON
Is the inspection result normal?
YES
NO
Check harness between combination meter and fuse.
3.CHECK EARTH CIRCUIT
  1. Turn ignition switch "LOCK" (OFF) position.
  2. Disconnect combination meter connector.
  3. Check continuity between combination meter harness connector and earth.
    Combination meter
    Earth
    Continuity
    Connector
    Terminal
    C-11
    14
    Existed
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent IncidentINTERMITTENT INCIDENT.
NO
Repair harness or connector.
BookmarkedToo many bookmarks.