ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - COMBINATION METER - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURES - COMBINATION METER BUZZER SIGNAL CIRCUIT
Diagnosis Procedure: Combination meter buzzer
N514281710000400ENG
1.CHECK COMBINATION METER BUZZER CIRCUIT FOR OPEN
  1. Turn ignition switch "LOCK" (OFF) position.
  2. Disconnect combination meter harness connector and combination meter buzzer harness connector.
  3. Check the continuity between combination meter harness connector and combination meter buzzer harness connector.
    Combination meter
    Combination meter buzzer
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-11
    17
    C-15
    1
    Existed
    18
    4
Is the inspection result normal?
YES
NO
Repair or replace malfunctioning parts.
2.CHECK COMBINATION METER BUZZER CIRCUIT FOR SHORT TO EARTH
Check the continuity between combination meter buzzer harness connector and earth.
Terminals
Continuity
(+)
(−)
Combination meter buzzer
Connector
Terminal
C-15
1
Earth
Not existed
4
Is the inspection result normal?
YES
NO
Repair or replace malfunctioning parts.
3.CHECK COMBINATION METER BUZZER CIRCUIT FOR SHORT TO POWER SUPPLY
  1. Turn ignition switch ON.
  2. Check the voltage between combination meter buzzer connector and body earth.
Terminals
Voltage
(Approx.)
(+)
(−)
Combination meter buzzer
Connector
Terminal
C-15
1
Body earth
0 V
4
Is the inspection result normal?
YES
Replace combination meter buzzer. Refer to COMBINATION METER BUZZER REMOVAL AND INSTALLATION.
NO
Repair or replace malfunctioning parts.