ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS FUNCTION
FREEZE FRAME DATA
N502634680000100ENG
When the DCU detects a malfunction and sets a diagnosis code, it also stores a current status of the urea SCR system.
This function is called "Freeze frame data." By analysing this "Freeze frame data" with the M.U.T.-III SE, an effective troubleshooting can be performed.
The display items of freeze frame data are shown below.
Display Item List
Item No.
Data item
Unit·Condition
1
ODO/TRIP METER
km
2
DTC count
count
3
Protection control operating state(urea injector 1)
ON or OFF
4
Urea injector 1 tip temperature
°C
5
SCR1 ammonia absorption
g
6
SCR2 ammonia absorption
7
SCR1 catalyst average temperature
°C
8
SCR2 catalyst average temperature
9
Urea consumption rate
g/km
10
Exhaust gas flow rate
kg/h
11
NOx sensor 1 received heat quantity
kJ
12
NOx sensor 3 received heat quantity
13
PM sensor received heat quantity
14
NOx sensor 1 heat quantity threshold
15
NOx sensor 3 heat quantity threshold
16
PM sensor heat quantity threshold
17
SCR system condition
Initial state, No pressure control, Pressure build-up, Pressure build-up completed, Decompression state, Air venting condition, Initial replenishment state, Sucking back completed state, Sucking back state, Ignition ON state
18
SCR system sub condition
No sub state, Pressure build-up preparation, Ventilation, Normal decompression, Decompression injector 1 open, Pressure sensor replacement, Decompression injector 2 open, System circulation, Successful initial filling, Initial decompression state, Decompressed state, Pump valve open state, Heat A(Urea tank-Piping), Defrost confirm supply pump, Thaw confirm suction pump, Heat B(hydro connector), Defrost confirm hydro connector, Urea pump re thawing, Defrost confirm urea pump
19
Urea tank level
mm
20
Urea injector 1 desired dosing quantity
mg/s
21
Urea backflow pump operating status
Deactivated, Freezing and defrosting, Pump active, Anti-freeze heating or Backflow pump passage fully open
22
NOx sensor 1 signal enable flag
ON or OFF
23
NOx sensor 3 signal enable flag
24
Ignition switch
25
PM sensor temperature
°C
26
Urea tank frozen state
Not frozen, Temperature retention mode, Suspected tank freeze, Tank freeze detection or NONE
27
Estimated ammonia concentration downstream SCR1
ppm
28
Estimated ammonia concentration downstream SCR2
29
Urea injection control status
Stop urea injection, Permission for urea injection, Restricted(NH3 slip), Stop(DPF regen requirement), Urea inj permit(regen prog), Stop(DPF regen temperature high), Restricted(exh system fail), Stop(regen required exh fail), Restricted(exh fail DPF regen)
30
Urea pressure sensor(filter value)
hPa
31
Urea level sensor status
No signal, Signal NG(short time), Signal OK(reception low), Signal OK(reception medium), Signal OK(reception high) or Signal OK(maximum reception)
32
Fuel injection quantity
mg/hub
33
Urea temperature sensor status
Available or Not available
34
Urea concentration signal status
NG(no signal), NG(sonar low quality), NG(sonar low constant), OK(sonar high quality small), OK(sonar high quality medium) or OK(sonar high quality large)
35
Engine speed
r/min
36
Vehicle speed
km/h
37
Ambient pressure
kPa
38
Battery voltage
V
39
Ambient temperature
°C
40
Urea Concentration
%
41
Urea Tank Temperature
°C
42
NOx sensor 1 detect concentration
ppm
43
NOx sensor 3 detect concentration
44
Urea tank remaining volume(L)
L
45
Vehicle acceleration(front/rear G)
m/s2
46
Vehicle acceleration(lateral G)
47
Duty of electrical water pump
%
48
SCR1 target ammonia absorption
g
49
SCR2 target ammonia absorption
50
DPF operation status
Normal mode, Regeneration mode or SCR Catalyst warm up mode
51
PM sensor status
Initialize(Sensor regeneration), Measurement, Sensor not ready or Regeneration finished
52
PM sensor current
uA
53
Number of moving detection of urea injector 1 valve
count
54
Urea tube heater current
A
55
Coolant temperature
°C
56
Urea tank level
%
57
Urea supply pump current(Pump lift stopped)
mA
58
O2 value(NOx sensor 1)
–
59
O2 value(NOx sensor 3)
60
EGR valve rate
%
61
Exhaust gas temperature sensor 1
°C
62
Exhaust gas temperature sensor 2
63
Exhaust gas temperature sensor 3
64
Urea tank heater current
A
BookmarkedToo many bookmarks.
Please delete and bookmark again.