ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS FUNCTION
FAIL-SAFE AND BACKUP FUNCTION
N502634890000100ENG
The control is carried out, which keeps the safety driving by the preset control logic when the diagnosis code is set. The diagnosis code having the fail-safe function is as follows.
Diagnosis code No.
Diagnosis item
Control Contents During malfunction
P0607-49
Control module
Urea SCR system shutdown. → Urea dosing is stopped.
P062F-00
Internal control module
P06EA-00
No.1 NOx Sensor Processor Performance
None
P2002-00
DPF Flow Resistance Below Limit
P202A-11
Reductant tank heater
Heater does not work when urea is frozen. → Urea dosing is stopped.
P202A-12
Reductant tank heater
P202A-13
Reductant tank heater
P202A-92
Urea Tank Heater Control Circuit Performance
P203A-01
Reductant level sensor A
None
P203A-11
Reductant level sensor A
P203A-12
Reductant level sensor A
P203A-1F
Reductant level sensor A
P203A-2A
Reductant level sensor A
P2047-11
Reductant injection valve unit 1 bank 1
P2047-12
Reductant injection valve unit 1 bank 1
P2047-13
Reductant injection valve unit 1 bank 1
P2047-73
Reductant injection valve unit 1 bank 1
P204A-01
Reductant pressure sensor
P204A-11
Reductant pressure sensor
P204A-12
Reductant pressure sensor
P204A-1C
Reductant pressure sensor
P204F-00
Reductant system bank 1
Urea SCR system shutdown. → Urea dosing is stopped.
P205A-11
Reductant tank temperature sensor
None
P205A-12
Reductant tank temperature sensor
P205A-1C
Urea Tank Temperature Sensor Circuit Range/Performance
P206A-11
Reductant quality sensor
P206A-12
Reductant quality sensor
P206A-1F
Reductant quality sensor
P208A-11
Reductant pump A
Urea SCR system shutdown. → Urea dosing is stopped.
P208A-12
Reductant pump A
P208A-13
Reductant pump A
P208A-92
Reductant pump A
None
P20B9-11
Reductant heater A
Heater does not work when urea is frozen. → Urea dosing is stopped.
P20B9-12
Reductant heater A
P20B9-13
Reductant heater A
P20B9-92
Urea Feed Tube Heater Control Circuit Performance
P20E8-00
Reductant pressure
Urea SCR system shutdown. → Urea dosing is stopped.
P20E9-00
Reductant pressure
P20EA-00
Reductant control module power relay
None
P20EB-00
Reductant control module power relay
P20EE-00
SCR Efficiency Below Threshold
P20F4-00
Reductant consumption
Urea SCR system shutdown. → Urea dosing is stopped.
P20F5-00
Reductant consumption
P20FA-11
Reductant pump B
None
P20FA-12
Reductant pump B
P20FA-13
Reductant pump B
P20FA-92
Reductant pump B
P21CA-11
Reductant control module
Urea SCR system shutdown. → Urea dosing is stopped.
P21CA-12
Reductant control module
P2200-01
NOx sensor 1 bank 1
None
P2200-1C
No.1 NOx Sensor Circuit Range/Performance
P2205-1C
No.1 NOx Sensor Heater Control Circuit Range/Performance
P220A-00
NOx sensor 1 bank 1
P225C-00
NOx sensor 1 bank 1
P225D-00
NOx sensor 1 bank 1
P22FB-00
NOx sensor 1 bank 1
P23AB-00
No.3 NOx Sensor Processor Performance
P23AC-01
NOx sensor 3 bank 1
P23AC-1C
No.3 NOx Sensor Circuit Range/Performance
P23B1-1C
No.3 NOx Sensor Heater Control Circuit Range/Performance
P23B6-00
NOx sensor 3 bank 1
P23BD-00
NOx sensor 3 bank 1
P23BE-00
NOx sensor 3 bank 1
P23C1-00
NOx sensor 3 bank 1
P24AE-01
PM Sensor Circuit
P24AE-12
PM Sensor Circuit High
P24AE-92
PM Sensor Circuit Range/Performance
P24B3-11
PM Sensor Heater Control Circuit Low
P24B3-12
PM Sensor Heater Control Circuit High
P24B3-1E
PM Sensor Heater Resistance
P24C6-01
PM Sensor Temperature Circuit
P24C6-11
PM Sensor Supply Voltage Circuit
P24C6-92
PM Sensor Temperature Circuit Range/Performance
P24DA-00
PM Sensor Exhaust Sample Error
P2BA7-00
NOx exceedance(empty reagent tank)
P2BA9-00
NOx exceedance
P33FA-1C
Power supply error(urea pressure sensor)
P33FB-1E
Urea injector 1
P33FD-1E
Supply pump
P33FE-1E
Backflow pump
P33FF-1C
Power supply error(urea tank temperature sensor)
U0100-00
Lost communication(ECM/PCM A)
U029D-00
Lost communication(NOx sensor A)
U02A1-00
Lost communication(NOx sensor C)
U02A3-00
Lost communication with PM Sensor
U0401-00
Invalid data(ECM/PCM A)
U04A4-00
Invalid Data Received from PM Sensor
U059E-00
Invalid data(NOx sensor A)
U05A4-00
PM sensor received invalid data from DCU
U05A8-00
Invalid data(NOx sensor C)
U0619-00
Lost communication(reductant level sensor A)
U0666-00
Lost communication(reductant pressure sensor)
U1350-86
Engine communication(exhaust gas mass flow)
U1351-86
Engine communication(engine speed)
U1352-86
Engine communication(ambient temperature)
U1353-81
SENT communication error(urea tank temperature sensor)
U1354-86
Engine communication(air flow sensor)
U1357-86
Engine communication(Accelerator pedal position)
U1358-86
Engine communication(vehicle acceleration)
U1359-86
Engine communication(EGR rate)
U135A-88
Engine CAN communication error(Bus off)
Urea SCR system shutdown. → Urea dosing is stopped.
U1360-86
Engine communication(EGR valve position)
None
U1361-86
Engine communication(coolant temperature)
U1362-86
Engine communication(Engine off time)
U1363-86
Engine communication(Throttle valve position)
U1365-86
Engine communication(vehicle speed)
U1366-86
Engine communication(ambient pressure)
U1368-86
Engine communication(air mass)
U1373-86
Engine communication(upstream SCR temperature 1)
U1374-86
Engine communication(downstream SCR temperature 1)
U1378-86
Engine communication(NOx value)
U1379-86
Engine communication(differential pressure sensor)
U1381-86
Engine communication(DPF regeneration request)
U1382-86
Engine communication(fuel injection quantity)
U1383-86
Engine communication(soot mass)
U1384-86
Engine communication(fuel total injection quantity)
U1385-86
Engine communication(soot mass)
U1386-86
Engine communication(ECU off time)
U1387-86
Engine communication(engine run time)
U1388-86
Engine communication(engine run time)