HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - CIRCUIT DIAGNOSIS PROCEDURE - FIN THERMO SENSOR
Diagnosis Procedure: Fin thermo sensor
N509002290000700ENG
1.CHECK FIN THERMO SENSOR
  1. Ignition switch "LOCK" (OFF) position.
  2. Check resistance between fin thermo sensor terminals. Refer to applicable table for the normal value.
    Terminal
    Condition
    Resistance: kΩ
    Temperature: °C
    H-03
    −20
    14.06
    −10
    8.12
    0
    4.85
    10
    2.96
    20
    1.87
    25
    1.50
    30
    1.21
    40
    0.81
Is the inspection result normal?
YES
INSPECTION END
NO
BookmarkedToo many bookmarks.