HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - CIRCUIT DIAGNOSIS PROCEDURE - BLOWER MOTOR
Diagnosis Procedure: Blower motor
N509002320000R00ENG
1.CHECK FUSE
  1. Ignition switch "LOCK" (OFF) position.
  2. Check that the following fusible link are not blown (open).
    Unit
    Location
    Fusible link No.
    Capacity
    Blower motor
    Fuse block (J/B)
    63
    40 A
Is the fuses blown (open)?
YES
Replace the blown (open) fusible link after repairing the affected circuit if a fusible link are blown (open).
NO
2.CHECK BLOWER MOTOR POWER SUPPLY
  1. Disconnect the blower motor connector.
  2. Ignition switch ON.
  3. Check voltage between blower motor harness connector and body earth.
    (+)
    (−)
    Voltage
    Blower motor
    Connector
    Terminal
    C-32
    1
    Body earth
    Battery voltage
Is the inspection result normal?
YES
NO
3.CHECK BLOWER MOTOR POWER SUPPLY CIRCUIT FOR OPEN
  1. Ignition switch "LOCK" (OFF) position.
  2. Disconnect fuse block (J/B) harness connector.
  3. Check continuity between fuse block (J/B) harness connector and blower motor harness connector.
    Fuse block (J/B)
    Blower motor
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-307
    1
    C-32
    1
    Existed
Is the inspection result normal?
YES
Repair the blower motor power supply circuit.
NO
Repair the harnesses or connectors.
4.CHECK BLOWER MOTOR CONTROL SIGNAL
  1. Connect power transistor connector.
  2. Ignition switch ON.
  3. Check duty ratios between power transistor harness connector and body earth by using an oscilloscope.
    (+)
    (−)
    Condition
    Output waveform
    Power transistor
    Connector
    Terminal
    C-31
    4
    Body earth
    Blower motor: OFF
    10.5 – 16 V
    Blower motor: 1st speed (manual)
    Blower motor: 7th speed (manual)
Is the inspection result normal?
YES
NO
5.CHECK BLOWER MOTOR CONTROL SIGNAL CIRCUIT FOR OPEN
  1. Ignition switch "LOCK" (OFF) position.
  2. Disconnect blower motor connector and power transistor connector.
  3. Check continuity between blower motor harness connector and power transistor harness connector.
    Blower motor
    Power transistor
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-32
    2
    C-31
    1
    Existed
Is the inspection result normal?
YES
NO
Repair the harnesses or connectors.
6.REPLACE BLOWER MOTOR
  1. Ignition switch ON.
  2. Change fan speed from 1st – 7th, and check that blower motor operates normally.
Is the inspection result normal?
YES
INSPECTION END
NO
Replace the power transistor. Refer to BLOWER MOTOR AND RESISTOR REMOVAL AND INSTALLATION.
BookmarkedToo many bookmarks.
Please delete and bookmark again.